Electric Distribution Panel
Item No.: | GCS |
Supplier Details
Country: China
City:
Address:
TEL: +--
Fax: +--

Online Showroom:
33 Products
GCS Cabinet is made of 8MF steel with excellent intensity, rigidity and thick plank materials. Its size and section area are much bigger than other types of profiled bar, therefore 8MF steel has much better intensity and rigidity than others.
The short-time withstand current of horizontal busbar and vertical busbar reaches 80kA/1S, and peak value can reach 176kA/1S, which is better than other types of switchgear cabinet on performance.
Various domestic and foreign types of breakers may be installed for GCS electric distribution panel according to customer requirements.
PC Cabinet can hold three switchgears at 1600A or below to reduce area and lower down cost. MCC Cabinet can be composed of five functional units, i.e. 0.5, 1, 1.5, 2, 3 (customers can choose standard type or economic type).
The pushing-in, pulling-out and control of switchgear are realized by the handle of operating system. The leveling of horizontal busbar ensures that there are passages at the top and bottom of cable chamber, which solves the problem that old products cannot be lined out. Electric components and affiliated parts are supplied by appointed manufacturers with perfect quality insurance system.
The short-time withstand current of horizontal busbar and vertical busbar reaches 80kA/1S, and peak value can reach 176kA/1S, which is better than other types of switchgear cabinet on performance.
Various domestic and foreign types of breakers may be installed for GCS electric distribution panel according to customer requirements.
PC Cabinet can hold three switchgears at 1600A or below to reduce area and lower down cost. MCC Cabinet can be composed of five functional units, i.e. 0.5, 1, 1.5, 2, 3 (customers can choose standard type or economic type).
The pushing-in, pulling-out and control of switchgear are realized by the handle of operating system. The leveling of horizontal busbar ensures that there are passages at the top and bottom of cable chamber, which solves the problem that old products cannot be lined out. Electric components and affiliated parts are supplied by appointed manufacturers with perfect quality insurance system.
Technical Parameters:
Rated voltage V | 380 | |
Rated frequency Hz | 50(60) | |
Rated current A | Horizontal busbar | ≤4000 |
Vertical busbar | 1000 | |
Rated busbar short withstand current kA(1S) | 50,80 | |
Rated busbar peak withstand current kA(0.1S) | 105,176 | |
Rated insulated voltage V | Three-phase four-wire system | 660(1000) |
Busbar system | Three-phase five-wire system | A,B,C,PEN |
Major circuit | A,B,V,PE,N | |
Power frequency test withstand voltage V(1min) | Ancillary circuit | 2500 |
1760 | ||
Rated voltage of assistant loop V | -220,380 -110,220 | |
Protection class | IP30,IP40 | |
Outside size width × depth × height(mm) | (400.600.800.1000)×(600.800.1000)×2200 |